| Assessment Year | 2002 |
|---|---|
| Principal Product | Emulsion Polymers |
| NAICS |
n/a
|
| SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
| Sales Range | $50 M to 100M |
| # of Employees | 75 |
| Plant Area |
750,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $535,261 | 7,848,116 |
kWh
|
$0.068 |
| Natural Gas | $31,154 | 12,729 |
MMBtu
|
$2.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $511,472 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $35,802 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7124: Make a practice of turning off lights when not needed | $10,037 | - |
$10,037
80,196
kWh
|
- | - | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $19,528 | $8,550 |
$19,528
163,472
kWh
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $16,476 | $6,382 |
$16,476
128,470
kWh
|
- | - | |
| 04 | 2.2622: Replace existing chiller with high efficiency model | $122,694 | $120,000 | n/a |
$122,694
1,027,068
kWh
|
- | - |
| 05 | 2.7132: Install timers on light switches in little used areas | $565 | $480 |
$565
4,524
kWh
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,326 | $23,370 |
$19,326
158,131
kWh
|
- | - | |
| 07 | 2.5123: Reduce fluid flow rates | $35,747 | $56,700 | n/a |
$35,747
268,088
kWh
|
- | - |
| 08 | 2.5123: Reduce fluid flow rates | $6,808 | $10,340 |
$6,808
51,997
kWh
|
- | - | |
| 09 | 2.5123: Reduce fluid flow rates | $2,958 | $5,070 |
$2,958
23,100
kWh
|
- | - | |
| 10 | 3.6192: Use a less expensive method of waste removal | $89,821 | $24,680 | - |
$89,821
-
lb
|
- | |
| 11 | 3.6192: Use a less expensive method of waste removal | $177,582 | $186,000 | - |
$177,582
-
lb
|
- | |
| 12 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $7,230 | $19,300 | - |
$7,230
-
lb
|
- | |
| 13 | 3.6192: Use a less expensive method of waste removal | $2,700 | $5,000 | - | - | $2,700 | |
| TOTAL RECOMMENDED | $511,472 | $465,872 |
$234,139
1,905,046
kWh
|
$274,633
-
lb
|
$2,700 | ||
| TOTAL IMPLEMENTED | $35,802 | $29,752 |
$35,802
286,601
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs