Assessment Year | 2001 |
---|---|
Principal Product | Catalyst Pellets |
NAICS |
n/a
|
SIC | 3819: |
Sales Range | $50 M to 100M |
# of Employees | 80 |
Plant Area |
1,350,360
ft2
|
Annual Production | 45,700,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $813,683 | 16,537,220 |
kWh
|
$0.049 |
Natural Gas | $1,579,580 | 282,907 |
MMBtu
|
$5.58 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $951,630 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $292,968 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|
01 | 3.7392: Apply a protective coating to racks and tanks | $3,452 | - |
$3,452
110,678
kWh
|
- | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $9,984 | $4,574 |
$9,984
393,120
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,711 | $1,366 |
$1,711
35,997
kWh
|
- | |
04 | 2.7132: Install timers on light switches in little used areas | $12,982 | $13,500 |
$12,982
263,859
kWh
|
- | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $46,103 | $50,000 |
$46,103
1,816,214
kWh
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $2,758 | $3,291 |
$2,758
55,450
kWh
|
- | |
07 | 2.7135: Install occupancy sensors | $6,547 | $14,341 |
$6,547
133,067
kWh
|
- | |
08 | 2.7132: Install timers on light switches in little used areas | $5,806 | $14,760 | n/a |
$5,806
118,015
kWh
|
- |
09 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,329 | $3,400 |
$1,329
52,416
kWh
|
- | |
10 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $33,374 | $128,000 | n/a |
$33,374
1,314,768
kWh
|
- |
11 | 3.6192: Use a less expensive method of waste removal | $219,121 | - | - |
$219,121
-
lb
|
|
12 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,216 | - | - |
$3,216
-
lb
|
|
13 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $461,186 | $60,000 | n/a | - |
$461,186
-
lb
|
14 | 4.111: Add equipment/ operators to reduce production bottleneck | $139,058 | $35,200 | n/a | - |
$139,058
-
lb
|
15 | 4.111: Add equipment/ operators to reduce production bottleneck | $5,003 | $5,111 | - |
$5,003
-
lb
|
|
TOTAL RECOMMENDED | $951,630 | $333,543 |
$124,046
4,293,584
kWh
|
$827,584
-
lb
|
||
TOTAL IMPLEMENTED | $292,968 | $77,317 |
$68,844
2,508,529
kWh
|
$224,124
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs