Assessment Year | 2000 |
---|---|
Principal Product | HDPE Bottles |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 35 |
Plant Area |
50,000
ft2
|
Annual Production | 94,000,000
units
|
Production Hrs. Annual | 6,936
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $425,439 | 5,010,240 |
kWh
|
$0.085 |
Natural Gas | $27,653 | 4,218 |
MMBtu
|
$6.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $84,591 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,937 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|
01 | 2.2691: Shut off cooling if cold outside air will cool process | $2,248 | - |
$2,248
26,534
kWh
|
- | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,267 | $781 |
$1,267
14,960
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,398 | $1,128 |
$1,398
16,396
kWh
|
- | |
04 | 2.2511: Insulate bare equipment | $4,536 | $4,508 |
$4,536
53,547
kWh
|
- | |
05 | 2.4133: Use most efficient type of electric motors | $8,404 | $9,230 |
$8,404
99,208
kWh
|
- | |
06 | 2.7135: Install occupancy sensors | $1,007 | $1,080 |
$1,007
11,888
kWh
|
- | |
07 | 2.7132: Install timers on light switches in little used areas | $568 | $750 |
$568
6,700
kWh
|
- | |
08 | 2.7135: Install occupancy sensors | $4,509 | $7,290 |
$4,509
53,227
kWh
|
- | |
09 | 2.7145: Install skylights | $8,242 | $23,962 |
$8,242
97,280
kWh
|
- | |
10 | 2.3212: Optimize plant power factor | $3,666 | $5,428 | - | $3,666 | |
11 | 2.8114: Change rate schedules or other changes in utility service | $48,746 | $120,000 | - | $48,746 | |
TOTAL RECOMMENDED | $84,591 | $174,157 |
$32,179
379,740
kWh
|
$52,412 | ||
TOTAL IMPLEMENTED | $23,937 | $24,767 |
$23,937
282,460
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs