Assessment Year | 2000 |
---|---|
Principal Product | Life Safety Explosives |
NAICS |
n/a
|
SIC | 3769: Guided Missile Space Vehicle Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 310 |
Plant Area |
180,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $267,460 | 3,134,779 |
kWh
|
$0.085 |
Electricity Demand | $719 | 8,439 |
kW-mo/yr
|
$0.085 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,218 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $36,831 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|
01 | 2.2223: Enhance sensitivity of temperature control and cutoff | $25,387 | $11,668 |
$25,387
298,155
kWh
|
- | |
02 | 2.7132: Install timers on light switches in little used areas | $5,898 | $3,720 |
$5,898
69,270
kWh
|
- | |
03 | 2.2514: Cover open tanks | $550 | $746 |
$550
6,447
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $29,331 | $57,900 |
$29,331
344,461
kWh
|
- | |
05 | 3.5313: Increase amount of waste recovered for resale | $1,052 | - | - |
$1,052
-
lb
|
|
TOTAL RECOMMENDED | $62,218 | $74,034 |
$61,166
718,333
kWh
|
$1,052
-
lb
|
||
TOTAL IMPLEMENTED | $36,831 | $62,366 |
$35,779
420,178
kWh
|
$1,052
-
lb
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs