| Assessment Year | 2000 |
|---|---|
| Principal Product | Sheet Metal |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
110,000
ft2
|
| Annual Production | 10,000,000
pieces
|
| Production Hrs. Annual | 4,550
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $73,668 | 894,600 |
kWh
|
$0.082 |
| Natural Gas | $75,917 | 15,413 |
MMBtu
|
$4.93 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,286 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,201 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $11,245 | $3,224 | - | - |
$11,245
-
MMBtu
|
- | |
| 02 | 2.2428: Use flue gases in radiant heater for space heating, ovens, etc | $8,529 | $3,300 | - | - |
$8,529
-
MMBtu
|
- | |
| 03 | 2.7132: Install timers on light switches in little used areas | $1,643 | $2,128 |
$1,447
15,200
kWh
|
$196
-
kW-mo/yr
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,402 | $5,673 |
$2,028
20,090
kWh
|
$374
-
kW-mo/yr
|
- | - | |
| 05 | 2.4133: Use most efficient type of electric motors | $3,316 | $6,961 |
$2,981
21,978
kWh
|
$335
-
kW-mo/yr
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,201 | $9,000 |
$1,900
19,436
kWh
|
$301
-
kW-mo/yr
|
- | - | |
| 07 | 3.6111: Use alternative flocculent to minimize sludge volume | $8,950 | $16,000 | - | - | - |
$8,950
-
lb
|
|
| TOTAL RECOMMENDED | $38,286 | $46,286 |
$8,356
76,704
kWh
|
$1,206
-
kW-mo/yr
|
$19,774
-
MMBtu
|
$8,950
-
lb
|
||
| TOTAL IMPLEMENTED | $2,201 | $9,000 |
$1,900
19,436
kWh
|
$301
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs