ITAC Assessment: SF0183
ITAC logo
ITAC Assessment: SF0183
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2000
Principal Product Chocolate Truffels
NAICS
n/a
SIC 2066: Chocolate and Cocoa Products
Sales Range $10
M
to 50
M
# of Employees 110
Plant Area 98,000
ft2
Annual Production 1,500,000
lb
Production Hrs. Annual 2,125
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $36,847 451,934
kWh
Electricity Demand $10,128 2,292
kW-mo/yr
Natural Gas $6,777 1,088
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $25,640 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Administrative Changes Savings
01 2.7134: Use photocell controls $718 $1,080 n/a $550
6,741
kWh
$168
-
kW-mo/yr
- - -
02 2.4133: Use most efficient type of electric motors $255 $638 n/a $212
2,638
kWh
$43
-
kW-mo/yr
- - -
03 2.7135: Install occupancy sensors $188 $480 n/a $144
1,758
kWh
$44
-
kW-mo/yr
- - -
04 2.7134: Use photocell controls $397 $1,400 n/a $304
3,810
kWh
$93
-
kW-mo/yr
- - -
05 3.6193: Install equipment (eg compactor) to reduce disposal costs $16,379 $1,915 n/a $(-87.0)
(-1,172)
kWh
- - $18,341
-
lb
$(-1,875.0)
06 2.4133: Use most efficient type of electric motors $7,703 $654 n/a $7,858
96,424
kWh
$2,404
-
kW-mo/yr
$(-2,559.0)
-
MMBtu
- -
TOTAL RECOMMENDED $25,640 $6,167 $8,981
110,199
kWh
$2,752
-
kW-mo/yr
$(-2,559.0)
-
MMBtu
$18,341
-
lb
$(-1,875.0)
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs