Assessment Year | 1999 |
---|---|
Principal Product | Polystyrene Loosefill |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $1 M to 5M |
# of Employees | 20 |
Plant Area |
41,000
ft2
|
Annual Production | 7,000,000
units
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,222 | 975,674 |
kWh
|
$0.081 |
Electricity Demand | $15,836 | 3,680 |
kW-mo/yr
|
$4.30 |
Natural Gas | $47,287 | 8,297 |
MMBtu
|
$5.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $188,310 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $358 | $451 |
$307
3,810
kWh
|
$51
-
kW-mo/yr
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $269 | $506 |
$232
2,931
kWh
|
$37
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $423 | $1,200 |
$365
4,396
kWh
|
$58
-
kW-mo/yr
|
- | - | |
04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $1,455 | $7,000 |
$1,255
15,533
kWh
|
$200
-
kW-mo/yr
|
- | - | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $14,305 | $14,475 | - | - |
$12,555
-
lb
|
$1,750 | |
06 | 4.513: Re-arrange equipment layout to reduce labor costs | $56,000 | - | - | - | - | $56,000 | |
07 | 4.652: Replace existing equipment with more suitable substitutes | $3,500 | $164 | - | - | - | $3,500 | |
08 | 4.513: Re-arrange equipment layout to reduce labor costs | $112,000 | $49,860 | - | - | - | $112,000 | |
TOTAL RECOMMENDED | $188,310 | $73,656 |
$2,159
26,670
kWh
|
$346
-
kW-mo/yr
|
$12,555
-
lb
|
$173,250 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs