Assessment Year | 1999 |
---|---|
Principal Product | Newspapers |
NAICS |
n/a
|
SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
25,000
ft2
|
Annual Production | 4,000,000
lb
|
Production Hrs. Annual | 3,640
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $61,970 | 1,114,009 |
kWh
|
$0.056 |
Electricity Demand | $20,875 | 3,498 |
kW-mo/yr
|
$5.97 |
Natural Gas | $6,183 | 860 |
MMBtu
|
$7.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $73,103 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,305 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $364 | - |
$364
6,448
kWh
|
- | - | - | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $368 | $495 |
$213
3,810
kWh
|
$155
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,488 | $22,530 |
$10,092
181,419
kWh
|
$5,396
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7135: Install occupancy sensors | $388 | $784 |
$224
4,103
kWh
|
$164
-
kW-mo/yr
|
- | - | - | - | |
05 | 3.5313: Increase amount of waste recovered for resale | $900 | $250 | - | - | - | - |
$900
-
lb
|
- | |
06 | 3.5217: Reuse / recycle/ sell paper products | $14,416 | $8,150 | - | - | - | - |
$13,636
-
lb
|
$780 | |
07 | 3.4151: Minimize water usage | $1,621 | $1,498 | - | - |
$1,621
-
Tgal
|
- | - | - | |
08 | 3.3122: Use filtration, centrifuging to remove contaminants | $1,400 | $4,280 | - | - | - |
$1,400
-
gal
|
- | - | |
09 | 4.445: Install equipment to move product | $36,400 | $10,100 | - | - | - | - | - | $36,400 | |
10 | 2.8112: Combine utility meters | $1,758 | $2,000 | - | - | - | - | - | $1,758 | |
TOTAL RECOMMENDED | $73,103 | $50,087 |
$10,893
195,780
kWh
|
$5,715
-
kW-mo/yr
|
$1,621
-
Tgal
|
$1,400
-
gal
|
$14,536
-
lb
|
$38,938 | ||
TOTAL IMPLEMENTED | $17,305 | $10,393 |
$213
3,810
kWh
|
$155
-
kW-mo/yr
|
$1,621
-
Tgal
|
- |
$14,536
-
lb
|
$780 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs