Assessment Year | 1999 |
---|---|
Principal Product | Dried Fruit |
NAICS |
n/a
|
SIC | 2034: Dried and Dehydrated Fruits, Vegetables, and Soup Mixes |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
110,000
ft2
|
Annual Production | 48,000
ton
|
Production Hrs. Annual | 5,352
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $377,390 | 6,837,046 |
kWh
|
$0.055 |
Electricity Demand | $192,216 | 17,640 |
kW-mo/yr
|
$10.90 |
Natural Gas | $454,550 | 152,683 |
MMBtu
|
$2.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $49,884 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2135: Repair and eliminate steam leaks | $9,860 | $175 | - | - |
$9,860
-
MMBtu
|
|
02 | 2.2121: Increase amount of condensate returned | $2,924 | - | - | - |
$2,924
-
MMBtu
|
|
03 | 2.4239: Eliminate or reduce compressed air usage | $7,516 | $1,500 |
$5,210
94,373
kWh
|
$2,306
-
kW-mo/yr
|
- | |
04 | 2.2121: Increase amount of condensate returned | $9,607 | $5,759 | - | - |
$9,607
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $1,796 | $1,080 |
$1,245
22,567
kWh
|
$551
-
kW-mo/yr
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $3,077 | $4,185 |
$2,146
38,980
kWh
|
$931
-
kW-mo/yr
|
- | |
07 | 2.2121: Increase amount of condensate returned | $5,150 | $8,430 | - | - |
$5,150
-
MMBtu
|
|
08 | 2.2123: Insulate feedwater tank | $601 | $1,327 | - | - |
$601
-
MMBtu
|
|
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,353 | $30,890 |
$6,486
117,526
kWh
|
$2,867
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $49,884 | $53,346 |
$15,087
273,446
kWh
|
$6,655
-
kW-mo/yr
|
$28,142
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs