Assessment Year 1999
Principal Product Packaging Film
NAICS
n/a
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $10
M
to 50
M
# of Employees 48
Plant Area 37,500
ft2
Annual Production 25,000,000
lb
Production Hrs. Annual 8,736
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $388,356 8,458,089
kWh
Electricity Demand $152,054 13,648
kW-mo/yr
Natural Gas $8,548 1,254
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $24,112 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,120

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $5,214 $1,519 $3,942
85,873
kWh
$1,272
-
kW-mo/yr
- -
02 2.2511: Insulate bare equipment $1,742 $800 - - $1,742
-
MMBtu
-
03 2.2614: Use cooling tower or economizer to replace chiller cooling $6,079 $5,335 $4,553
99,062
kWh
$1,526
-
kW-mo/yr
- -
04 2.4133: Use most efficient type of electric motors $1,303 $1,141 $977
21,395
kWh
$326
-
kW-mo/yr
- -
05 2.7135: Install occupancy sensors $756 $1,008 $516
11,137
kWh
$240
-
kW-mo/yr
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $8,640 $22,110 $5,777
125,733
kWh
$2,863
-
kW-mo/yr
- -
07 3.5313: Increase amount of waste recovered for resale $378 - - - - $378
-
lb
TOTAL RECOMMENDED $24,112 $31,913 $15,765
343,200
kWh
$6,227
-
kW-mo/yr
$1,742
-
MMBtu
$378
-
lb
TOTAL IMPLEMENTED $2,120 $800 - - $1,742
-
MMBtu
$378
-
lb
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs