Assessment Year | 1998 |
---|---|
Principal Product | Commercial Printing |
NAICS |
n/a
|
SIC | 2799: |
Sales Range | $10 M to 50M |
# of Employees | 82 |
Plant Area |
44,000
ft2
|
Annual Production | 500
ton
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $97,786 | 1,200,469 |
kWh
|
$0.081 |
Electricity Demand | $18,184 | 4,279 |
kW-mo/yr
|
$4.25 |
Natural Gas | $1,121 | 145 |
MMBtu
|
$7.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $228,420 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,772 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $1,612 | $2,400 |
$1,391
16,999
kWh
|
$221
-
kW-mo/yr
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $373 | $607 |
$320
3,810
kWh
|
$53
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,399 | $31,690 |
$10,794
132,474
kWh
|
$1,605
-
kW-mo/yr
|
- | - | |
04 | 3.5313: Increase amount of waste recovered for resale | $787 | $125 | - | - |
$787
-
lb
|
- | |
05 | 4.422: Utilize outside contracting | $213,249 | - |
$11,804
144,783
kWh
|
$1,445
-
kW-mo/yr
|
- | $200,000 | |
TOTAL RECOMMENDED | $228,420 | $34,822 |
$24,309
298,066
kWh
|
$3,324
-
kW-mo/yr
|
$787
-
lb
|
$200,000 | ||
TOTAL IMPLEMENTED | $12,772 | $32,297 |
$11,114
136,284
kWh
|
$1,658
-
kW-mo/yr
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs