Assessment Year | 1998 |
---|---|
Principal Product | Applesauce,Applejuice,and Apple Vinegar |
NAICS |
n/a
|
SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
Sales Range | $5 M to 10M |
# of Employees | 0 |
Plant Area |
100,000
ft2
|
Annual Production | 7,630
ton
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $82,902 | 986,225 |
kWh
|
$0.084 |
Electricity Demand | $14,092 | 3,182 |
kW-mo/yr
|
$4.43 |
Natural Gas | $76,723 | 22,550 |
MMBtu
|
$3.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,801 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,120 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,167 | $156 |
$2,602
31,067
kWh
|
$565
-
kW-mo/yr
|
- | - | |
02 | 2.7124: Make a practice of turning off lights when not needed | $878 | - |
$545
6,448
kWh
|
$333
-
kW-mo/yr
|
- | - | |
03 | 2.2121: Increase amount of condensate returned | $1,152 | $1,611 | - | - |
$1,152
-
MMBtu
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $675 | $967 |
$517
6,155
kWh
|
$158
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,803 | $7,808 |
$2,281
27,257
kWh
|
$522
-
kW-mo/yr
|
- | - | |
06 | 2.1242: Minimize boiler blowdown with better feedwater treatment | $610 | $3,500 | - | - |
$610
-
MMBtu
|
- | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $516 | - | - | - | - |
$516
-
lb
|
|
TOTAL RECOMMENDED | $9,801 | $14,042 |
$5,945
70,927
kWh
|
$1,578
-
kW-mo/yr
|
$1,762
-
MMBtu
|
$516
-
lb
|
||
TOTAL IMPLEMENTED | $6,120 | $6,234 |
$3,119
37,222
kWh
|
$723
-
kW-mo/yr
|
$1,762
-
MMBtu
|
$516
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs