Assessment Year 1997
Principal Product Printed Advertising Material
NAICS
n/a
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 175
Plant Area 40,000
ft2
Annual Production 480,000,000
pieces
Production Hrs. Annual 6,864
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $148,716 2,507,034
kWh
Electricity Demand $83,535 6,366
kW-mo/yr
Natural Gas $144,748 42,082
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $65,854 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $60,082

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Water Disposal Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $5,721 $11,940 $3,502
58,910
kWh
$2,219
-
kW-mo/yr
- - - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $6,837 $15,200 $5,047
84,994
kWh
$1,790
-
kW-mo/yr
- - - -
03 2.4133: Use most efficient type of electric motors $757 $767 $556
9,379
kWh
$201
-
kW-mo/yr
- - - -
04 2.7135: Install occupancy sensors $824 $2,025 $824
13,775
kWh
- - - - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,884 - $3,299
55,686
kWh
$585
-
kW-mo/yr
- - - -
06 2.4239: Eliminate or reduce compressed air usage $309 $327 $228
3,810
kWh
$81
-
kW-mo/yr
- - - -
07 2.4239: Eliminate or reduce compressed air usage $296 $920 $160
2,638
kWh
$136
-
kW-mo/yr
- - - -
08 2.3212: Optimize plant power factor $1,969 $3,215 - - $1,969 - - -
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,606 $1,256 $1,923
32,239
kWh
$683
-
kW-mo/yr
- - - -
10 2.4231: Reduce the pressure of compressed air to the minimum required $1,485 $15 $1,096
18,464
kWh
$389
-
kW-mo/yr
- - - -
11 3.5315: Lease / purchase baler; sell cardboard to recycler $2,726 - - - - - $2,726
-
lb
-
12 3.5313: Increase amount of waste recovered for resale $4,574 - - - - - $4,574
-
lb
-
13 3.5313: Increase amount of waste recovered for resale $17,820 $8,275 - - - - $17,820
-
lb
-
14 3.5313: Increase amount of waste recovered for resale $3,000 $150 - - - - $3,000
-
lb
-
15 3.1192: Reduce scrap production $1,225 $1,000 - - - - $1,225
-
lb
-
16 3.4151: Minimize water usage $901 $1,357 - - - $901
-
Tgal
- -
17 4.423: Move product using mechanical means $10,920 $30,000 - - - - - $10,920
TOTAL RECOMMENDED $65,854 $76,447 $16,635
279,895
kWh
$6,084
-
kW-mo/yr
$1,969 $901
-
Tgal
$29,345
-
lb
$10,920
TOTAL IMPLEMENTED $60,082 $69,699 $14,552
245,018
kWh
$5,265
-
kW-mo/yr
- - $29,345
-
lb
$10,920
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Water Disposal Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs