ITAC Assessment: SF0117
ITAC logo
ITAC Assessment: SF0117
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1997
Principal Product Frozen Vegetables
NAICS
n/a
SIC 2037: Frozen Fruits, Fruit Juices, and Vegetables
Sales Range $5
M
to 10
M
# of Employees 130
Plant Area 200,000
ft2
Annual Production 40,000,000
lb
Production Hrs. Annual 8,760
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $348,215 6,902,403
kWh
Electricity Demand $120,421 14,606
kW-mo/yr
Natural Gas $165 70
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $380,862 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $19,419

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings Primary Product Savings
01 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $9,796 $8,000 $9,796
194,021
kWh
- - - -
02 2.4133: Use most efficient type of electric motors $1,008 $1,021 $799
15,826
kWh
$209
-
kW-mo/yr
- - -
03 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $124,200 $18,900 $108,238
2,145,662
kWh
$15,962
-
kW-mo/yr
- - -
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,213 $819 $1,069
21,102
kWh
$144
-
kW-mo/yr
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,308 $4,020 $746
14,654
kWh
$562
-
kW-mo/yr
- - -
06 2.3132: Recharge batteries on during off-peak demand periods $1,499 - - - $1,499 - -
07 2.2531: Re-size charging openings or add movable cover or door $5,025 $150 $5,025
99,648
kWh
- - - -
08 3.5313: Increase amount of waste recovered for resale $12,173 $150 - - - $12,173
-
lb
-
09 4.441: Install automatic packing equipment $224,640 $200,000 - - - - $224,640
TOTAL RECOMMENDED $380,862 $233,060 $125,673
2,490,913
kWh
$16,877
-
kW-mo/yr
$1,499 $12,173
-
lb
$224,640
TOTAL IMPLEMENTED $19,419 $2,140 $6,893
136,576
kWh
$353
-
kW-mo/yr
- $12,173
-
lb
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs