| Assessment Year | 1997 |
|---|---|
| Principal Product | Frozen Vegetables |
| NAICS |
n/a
|
| SIC | 2037: Frozen Fruits, Fruit Juices, and Vegetables |
| Sales Range | $5 M to 10M |
| # of Employees | 130 |
| Plant Area |
200,000
ft2
|
| Annual Production | 40,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $348,215 | 6,902,403 |
kWh
|
$0.050 |
| Electricity Demand | $120,421 | 14,606 |
kW-mo/yr
|
$8.24 |
| Natural Gas | $165 | 70 |
MMBtu
|
$2.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $380,862 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,419 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $9,796 | $8,000 |
$9,796
194,021
kWh
|
- | - | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $1,008 | $1,021 |
$799
15,826
kWh
|
$209
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $124,200 | $18,900 |
$108,238
2,145,662
kWh
|
$15,962
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,213 | $819 |
$1,069
21,102
kWh
|
$144
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,308 | $4,020 |
$746
14,654
kWh
|
$562
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.3132: Recharge batteries on during off-peak demand periods | $1,499 | - | - | - | $1,499 | - | - | |
| 07 | 2.2531: Re-size charging openings or add movable cover or door | $5,025 | $150 |
$5,025
99,648
kWh
|
- | - | - | - | |
| 08 | 3.5313: Increase amount of waste recovered for resale | $12,173 | $150 | - | - | - |
$12,173
-
lb
|
- | |
| 09 | 4.441: Install automatic packing equipment | $224,640 | $200,000 | - | - | - | - | $224,640 | |
| TOTAL RECOMMENDED | $380,862 | $233,060 |
$125,673
2,490,913
kWh
|
$16,877
-
kW-mo/yr
|
$1,499 |
$12,173
-
lb
|
$224,640 | ||
| TOTAL IMPLEMENTED | $19,419 | $2,140 |
$6,893
136,576
kWh
|
$353
-
kW-mo/yr
|
- |
$12,173
-
lb
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs