Assessment Year | 1997 |
---|---|
Principal Product | Metal Cabinet for Technology Companies |
NAICS |
n/a
|
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 95 |
Plant Area |
55,000
ft2
|
Annual Production | 360,000
ton
|
Production Hrs. Annual | 5,096
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $74,912 | 890,094 |
kWh
|
$0.084 |
Electricity Demand | $12,435 | 2,867 |
kW-mo/yr
|
$4.34 |
Natural Gas | $4,584 | 765 |
MMBtu
|
$5.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $39,449 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,016 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $455 | $516 |
$395
4,689
kWh
|
$60
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,043 | - |
$930
11,137
kWh
|
$113
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,131 | $20,040 |
$4,345
51,583
kWh
|
$786
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7135: Install occupancy sensors | $498 | $1,232 |
$402
4,689
kWh
|
$96
-
kW-mo/yr
|
- | - | - | - | |
05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $390 | $250 | - | - | - |
$390
-
lb
|
- | - | |
06 | 3.2124: Convert to air assisted / airless paint guns | $5,935 | $5,245 | - | - |
$1,775
-
gal
|
- | $4,160 | - | |
07 | 4.321: Optimize production lot sizes and inventories | $25,000 | $1,600 | - | - | - | - | - | $25,000 | |
08 | 3.5313: Increase amount of waste recovered for resale | $997 | - | - | - | - |
$3,597
-
lb
|
$(-2,600.0) | - | |
TOTAL RECOMMENDED | $39,449 | $28,883 |
$6,072
72,098
kWh
|
$1,055
-
kW-mo/yr
|
$1,775
-
gal
|
$3,987
-
lb
|
$1,560 | $25,000 | ||
TOTAL IMPLEMENTED | $8,016 | $20,806 |
$5,670
67,409
kWh
|
$959
-
kW-mo/yr
|
- |
$3,987
-
lb
|
$(-2,600.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs