Assessment Year | 1997 |
---|---|
Principal Product | Injection Molding Parts |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
100,000
ft2
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $131,382 | 1,474,795 |
kWh
|
$0.089 |
Electricity Demand | $21,249 | 5,124 |
kW-mo/yr
|
$4.15 |
Natural Gas | $5,239 | 734 |
MMBtu
|
$7.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,047 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,019 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $119 | $11,984 |
$23
7,327
kWh
|
$96
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,990 | $16,568 |
$5,521
61,841
kWh
|
$1,469
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $435 | $360 |
$343
3,810
kWh
|
$92
-
kW-mo/yr
|
- | - | |
04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $1,601 | $7,400 |
$1,262
14,068
kWh
|
$339
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,713 | - |
$2,490
27,843
kWh
|
$223
-
kW-mo/yr
|
- | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $1,365 | $3,180 |
$905
10,258
kWh
|
$460
-
kW-mo/yr
|
- | - | |
07 | 2.6218: Turn off equipment when not in use | $3,395 | - |
$3,116
34,877
kWh
|
$279
-
kW-mo/yr
|
- | - | |
08 | 2.2511: Insulate bare equipment | $766 | $2,301 |
$766
8,499
kWh
|
- | - | - | |
09 | 3.1121: Use more efficient adhesive applicators | $7,120 | $5,285 | - | - |
$4,680
-
lb
|
$2,440 | |
10 | 4.122: Develop standard procedures to improve internal yields | $2,543 | $1,200 | - | - | - | $2,543 | |
TOTAL RECOMMENDED | $27,047 | $48,278 |
$14,426
168,523
kWh
|
$2,958
-
kW-mo/yr
|
$4,680
-
lb
|
$4,983 | ||
TOTAL IMPLEMENTED | $16,019 | $38,613 |
$13,521
158,265
kWh
|
$2,498
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |