Assessment Year | 1996 |
---|---|
Principal Product | Plastic Injection Parts |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 40 |
Plant Area |
13,000
ft2
|
Annual Production | 4,000,000
pieces
|
Production Hrs. Annual | 2,800
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,326 | 483,587 |
kWh
|
$0.090 |
Electricity Demand | $8,985 | 2,160 |
kW-mo/yr
|
$4.16 |
Natural Gas | $851 | 100 |
MMBtu
|
$8.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,757 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,329 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $183 | $653 |
$146
1,758
kWh
|
$37
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,146 | $12,480 |
$2,556
28,429
kWh
|
$590
-
kW-mo/yr
|
- | - | - | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,762 | $1,975 |
$2,016
22,567
kWh
|
$562
-
kW-mo/yr
|
$(-816.0)
-
MMBtu
|
- | - | |
04 | 2.2511: Insulate bare equipment | $4,296 | $8,880 |
$4,296
48,066
kWh
|
- | - | - | - | |
05 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $10,370 | $500 | - | - | - |
$3,265
-
lb
|
$7,105 | |
TOTAL RECOMMENDED | $19,757 | $24,488 |
$9,014
100,820
kWh
|
$1,189
-
kW-mo/yr
|
$(-816.0)
-
MMBtu
|
$3,265
-
lb
|
$7,105 | ||
TOTAL IMPLEMENTED | $3,329 | $13,133 |
$2,702
30,187
kWh
|
$627
-
kW-mo/yr
|
- | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs