| Assessment Year | 1996 |
|---|---|
| Principal Product | Wooden Countertops |
| NAICS |
n/a
|
| SIC | 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers |
| Sales Range | $1 M to 5M |
| # of Employees | 23 |
| Plant Area |
25,000
ft2
|
| Annual Production | 520
thousand feet
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $31,176 | 311,254 |
kWh
|
$0.10 |
| Electricity Demand | $5,732 | 1,368 |
kW-mo/yr
|
$4.19 |
| Natural Gas | $2,257 | 278 |
MMBtu
|
$8.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,115 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,414 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,684 | $11,906 |
$3,684
36,635
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $913 | $3,000 |
$765
7,620
kWh
|
$148
-
kW-mo/yr
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $221 | $281 |
$183
1,758
kWh
|
$38
-
kW-mo/yr
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $280 | - |
$251
2,345
kWh
|
$29
-
kW-mo/yr
|
- | |
| 05 | 3.5313: Increase amount of waste recovered for resale | $1,017 | - | - | - |
$1,017
-
lb
|
|
| TOTAL RECOMMENDED | $6,115 | $15,187 |
$4,883
48,358
kWh
|
$215
-
kW-mo/yr
|
$1,017
-
lb
|
||
| TOTAL IMPLEMENTED | $1,414 | $3,281 |
$1,199
11,723
kWh
|
$215
-
kW-mo/yr
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs