Assessment Year | 1996 |
---|---|
Principal Product | Plastic Extrusions |
NAICS |
n/a
|
SIC | 3082: Unsupported Plastics Profile Shapes |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
36,000
ft2
|
Annual Production | 3,700,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $105,165 | 2,462,778 |
kWh
|
$0.043 |
Electricity Demand | $36,985 | 5,558 |
kW-mo/yr
|
$6.65 |
Natural Gas | $4,110 | 578 |
MMBtu
|
$7.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,038 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,904 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $606 | $464 |
$507
11,723
kWh
|
$99
-
kW-mo/yr
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,317 | $2,110 |
$3,273
17,878
kWh
|
$1,044
-
kW-mo/yr
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $981 | $810 |
$753
17,585
kWh
|
$228
-
kW-mo/yr
|
- | |
04 | 3.5314: Use in-process recycling whenever possible | $1,134 | $100 | - | - |
$1,134
-
lb
|
|
TOTAL RECOMMENDED | $7,038 | $3,484 |
$4,533
47,186
kWh
|
$1,371
-
kW-mo/yr
|
$1,134
-
lb
|
||
TOTAL IMPLEMENTED | $5,904 | $3,384 |
$4,533
47,186
kWh
|
$1,371
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs