Assessment Year | 1995 |
---|---|
Principal Product | Aluminum, Brass, and Zinc Die Castings |
NAICS |
n/a
|
SIC | 3363: Aluminum Die-Castings |
Sales Range | $5 M to 10M |
# of Employees | 90 |
Plant Area |
36,000
ft2
|
Annual Production | 1,080,000
lb
|
Production Hrs. Annual | 4,784
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $184,587 | 1,574,443 |
kWh
|
$0.12 |
Natural Gas | $129,349 | 28,677 |
MMBtu
|
$4.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,860 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,428 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,011 | $1,077 |
$1,011
8,499
kWh
|
- | |
02 | 2.7135: Install occupancy sensors | $11,092 | $7,040 |
$11,092
94,666
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $848 | $526 |
$848
7,327
kWh
|
- | |
04 | 2.4314: Use synthetic lubricant | $580 | $732 |
$580
4,982
kWh
|
- | |
05 | 2.2123: Insulate feedwater tank | $727 | $140 | - |
$727
-
MMBtu
|
|
06 | 2.2511: Insulate bare equipment | $27,226 | $4,400 | - |
$27,226
-
MMBtu
|
|
07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,376 | $5,725 |
$1,646
14,068
kWh
|
$(-270.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $42,860 | $19,640 |
$15,177
129,542
kWh
|
$27,683
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,428 | $1,258 |
$1,428
12,309
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs