ITAC Assessment: SF0049
ITAC logo
ITAC Assessment: SF0049
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Precision Aluminum Die Castings
NAICS
n/a
SIC 3363: Aluminum Die-Castings
Sales Range $5
M
to 10
M
# of Employees 60
Plant Area 50,000
ft2
Annual Production 2,000,000
pieces
Production Hrs. Annual 3,750
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $163,977 1,356,682
kWh
Natural Gas $16,423 2,573
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $10,906 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $10,684

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4133: Use most efficient type of electric motors $517 $694 $517
4,982
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $5,351 $18,749 $5,351
44,256
kWh
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,816 $1,000 $4,816
39,859
kWh
04 2.6218: Turn off equipment when not in use $222 $1,250 $222
1,758
kWh
TOTAL RECOMMENDED $10,906 $21,693 $10,906
90,855
kWh
TOTAL IMPLEMENTED $10,684 $20,443 $10,684
89,097
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs