| Assessment Year | 1994 |
|---|---|
| Principal Product | Infrared Detectors |
| NAICS |
n/a
|
| SIC | 3674: Semiconductors and Related Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 110 |
| Plant Area |
40,000
ft2
|
| Annual Production | 47,800
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $163,248 | 1,517,585 |
kWh
|
$0.11 |
| Natural Gas | $2,523 | 390 |
MMBtu
|
$6.47 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,814 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,380 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,462 | $10,810 |
$6,462
64,771
kWh
|
|
| 02 | 2.6218: Turn off equipment when not in use | $4,033 | - |
$4,033
40,445
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $440 | $123 |
$440
4,396
kWh
|
|
| 04 | 2.7135: Install occupancy sensors | $918 | $1,316 |
$918
9,086
kWh
|
|
| 05 | 2.6218: Turn off equipment when not in use | $338 | $600 |
$338
3,517
kWh
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $623 | $540 |
$623
6,155
kWh
|
|
| TOTAL RECOMMENDED | $12,814 | $13,389 |
$12,814
128,370
kWh
|
||
| TOTAL IMPLEMENTED | $7,380 | $12,126 |
$7,380
73,857
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs