| Assessment Year | 1994 |
|---|---|
| Principal Product | Thin Film Coating |
| NAICS |
n/a
|
| SIC | 3827: Optical Instruments and Lenses |
| Sales Range | $5 M to 10M |
| # of Employees | 50 |
| Plant Area |
50,000
ft2
|
| Annual Production | 90
ton
|
| Production Hrs. Annual | 4,680
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $142,945 | 1,234,174 |
kWh
|
$0.12 |
| Natural Gas | $1,527 | 194 |
MMBtu
|
$7.87 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,037 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,509 | $1,549 |
$1,509
12,896
kWh
|
|
| 02 | 2.6218: Turn off equipment when not in use | $1,086 | $350 |
$1,086
9,379
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $852 | $1,663 |
$852
7,327
kWh
|
|
| 04 | 2.7135: Install occupancy sensors | $848 | $949 |
$848
7,327
kWh
|
|
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $742 | $1,200 |
$742
9,086
kWh
|
|
| TOTAL RECOMMENDED | $5,037 | $5,711 |
$5,037
46,015
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs