Assessment Year | 1993 |
---|---|
Principal Product | Ferrous Castings |
NAICS |
n/a
|
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
41,000
ft2
|
Annual Production | 2,187
ton
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $206,268 | 1,987,397 |
kWh
|
$0.10 |
Natural Gas | $29,276 | 5,473 |
MMBtu
|
$5.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,608 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,863 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,691 | $1,500 |
$11,691
140,973
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $3,019 | $7,074 |
$3,019
29,015
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,004 | $2,096 |
$1,004
9,672
kWh
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,853 | $17,500 |
$8,853
85,287
kWh
|
- | |
05 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $1,892 | $8,189 | - |
$1,892
-
MMBtu
|
|
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,149 | $2,500 | - |
$3,149
-
MMBtu
|
|
TOTAL RECOMMENDED | $29,608 | $38,859 |
$24,567
264,947
kWh
|
$5,041
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,863 | $13,170 |
$15,714
179,660
kWh
|
$3,149
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs