Assessment Year | 1993 |
---|---|
Principal Product | Non Ferrous Castings |
NAICS |
n/a
|
SIC | 3363: Aluminum Die-Castings |
Sales Range | $1 M to 5M |
# of Employees | 19 |
Plant Area |
40,000
ft2
|
Annual Production | 215,000
lb
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $66,402 | 463,951 |
kWh
|
$0.14 |
Natural Gas | $16,658 | 2,920 |
MMBtu
|
$5.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,438 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,744 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,926 | $600 |
$1,926
13,482
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $1,220 | $1,916 |
$1,220
8,499
kWh
|
|
03 | 2.8114: Change rate schedules or other changes in utility service | $694 | $1,000 |
$694
-
kWh
|
|
04 | 2.7134: Use photocell controls | $464 | $430 |
$464
3,224
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $134 | $262 |
$134
879
kWh
|
|
TOTAL RECOMMENDED | $4,438 | $4,208 |
$4,438
26,084
kWh
|
||
TOTAL IMPLEMENTED | $3,744 | $3,208 |
$3,744
26,084
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs