Assessment Year 1993
Principal Product Non Ferrous Castings
NAICS
n/a
SIC 3363: Aluminum Die-Castings
Sales Range $1
M
to 5
M
# of Employees 19
Plant Area 40,000
ft2
Annual Production 215,000
lb
Production Hrs. Annual 2,500
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $66,402 463,951
kWh
Natural Gas $16,658 2,920
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $4,438 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,744

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,926 $600 $1,926
13,482
kWh
02 2.4133: Use most efficient type of electric motors $1,220 $1,916 $1,220
8,499
kWh
03 2.8114: Change rate schedules or other changes in utility service $694 $1,000 $694
-
kWh
04 2.7134: Use photocell controls $464 $430 $464
3,224
kWh
05 2.7142: Utilize higher efficiency lamps and/or ballasts $134 $262 $134
879
kWh
TOTAL RECOMMENDED $4,438 $4,208 $4,438
26,084
kWh
TOTAL IMPLEMENTED $3,744 $3,208 $3,744
26,084
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs