Assessment Year | 1993 |
---|---|
Principal Product | Electric Furnaces and Heating Elements |
NAICS |
n/a
|
SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
25,000
ft2
|
Annual Production | 1,500
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $87,536 | 759,672 |
kWh
|
$0.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,921 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $7,604 | $8,000 |
$7,604
-
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,907 | $4,404 |
$2,907
25,205
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $410 | $525 |
$410
4,103
kWh
|
|
TOTAL RECOMMENDED | $10,921 | $12,929 |
$10,921
29,308
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs