| Assessment Year | 2026 |
|---|---|
| Principal Product | Craft Beer and Beverages |
| NAICS | 312120: Breweries |
| SIC | 2082: Malt Beverages |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
15,000
ft2
|
| Annual Production | 75,000
units
|
| Production Hrs. Annual | 3,875
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $139,808 | 945,768 |
kWh
|
$0.15 |
| Electricity Demand | $237,075 | 3,095 |
kW-mo/yr
|
$76.60 |
| Electricity Fees | $8,583 | - |
|
- |
| Natural Gas | $92,667 | 6,721 |
MMBtu
|
$13.79 |
| TOTAL YEARLY COSTS | $478,133 | |||
| RECOMMENDED SAVINGS* | $295,910 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3141: Use battery storage for demand control | $258,060 | $497,690 |
$(-3,912.0)
(-26,471)
kWh
|
$261,972
-
kW-mo/yr
|
- | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,471 | $11,400 |
$5,554
37,580
kWh
|
$8,916
-
kW-mo/yr
|
- | |
| 03 | 2.2135: Repair and eliminate steam leaks | $8,519 | $600 | - | - |
$8,519
-
MMBtu
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $4,248 | $7,693 |
$1,631
11,034
kWh
|
$2,617
-
kW-mo/yr
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,825 | $2,030 |
$1,852
12,532
kWh
|
$2,973
-
kW-mo/yr
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,025 | - |
$2,025
13,703
kWh
|
- | - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $439 | $1,355 |
$169
1,141
kWh
|
$270
-
kW-mo/yr
|
- | |
| 08 | 2.2414: Use waste heat from hot flue gases to preheat | $3,323 | $1,671 | - | - |
$3,323
-
MMBtu
|
|
| TOTAL RECOMMENDED | $295,910 | $522,439 |
$7,319
49,518
kWh
|
$276,749
-
kW-mo/yr
|
$11,842
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs