Assessment Year | 2023 |
---|---|
Principal Product | Hot Isostatic Material Pressing. |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 39 |
Plant Area |
13,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $127,560 | 1,344,505 |
kWh
|
$0.095 | |
Electricity Demand | $404,377 | 11,088 |
kW-mo/yr
|
$36.47 | |
Electricity Fees | $26,659 | - |
|
- | |
Waste Disposal Costs | |||||
Other Liquid (non-haz) | $498,543 | 1,147,500 |
gal
|
$0.43 | |
TOTAL YEARLY COSTS | $1,057,139 | ||||
RECOMMENDED SAVINGS* | $160,829 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $160,829 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $55,294 | $90,412 |
$21,683
228,480
kWh
|
$33,611
-
kW-mo/yr
|
- | |
02 | 2.3141: Use battery storage for demand control | $15,758 | - |
$(-2,732.0)
(-28,793)
kWh
|
$18,490
-
kW-mo/yr
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $9,572 | $31,410 |
$4,517
47,597
kWh
|
$5,055
-
kW-mo/yr
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,271 | $4,317 |
$781
8,226
kWh
|
$490
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,109 | $18,901 |
$1,170
12,327
kWh
|
$2,939
-
kW-mo/yr
|
- | |
06 | 2.7232: Replace existing hvac unit with high efficiency model | $5,370 | $18,675 |
$684
7,209
kWh
|
$4,686
-
kW-mo/yr
|
- | |
07 | 3.5311: Recover and reuse waste material | $69,455 | $136,016 |
$(-10,454.0)
(-110,160)
kWh
|
$(-19,694.0)
-
kW-mo/yr
|
$99,603
-
gal
|
|
TOTAL RECOMMENDED | $160,829 | $299,731 |
$15,649
164,886
kWh
|
$45,577
-
kW-mo/yr
|
$99,603
-
gal
|
||
TOTAL IMPLEMENTED | $160,829 | $299,731 |
$15,649
164,886
kWh
|
$45,577
-
kW-mo/yr
|
$99,603
-
gal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings |