Assessment Year | 2023 |
---|---|
Principal Product | Metal Bellows and Metal Hoses |
NAICS | 332510: Hardware Manufacturing |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
54,000
ft2
|
Annual Production | 500,000
units
|
Production Hrs. Annual | 4,950
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $111,346 | 488,588 |
kWh
|
$0.23 |
Electricity Demand | $96,573 | 1,661 |
kW-mo/yr
|
$58.16 |
Electricity Fees | $(-45,866.0) | - |
|
- |
TOTAL YEARLY COSTS | $162,053 | |||
RECOMMENDED SAVINGS* | $269,965 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,654 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,805 | $300 |
$1,805
7,920
kWh
|
- | - | |
02 | 2.3134: Shift from daytime to nighttime operation | $28,974 | - | - |
$28,974
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $2,227 | $4,339 |
$1,376
6,036
kWh
|
$851
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,654 | $4,172 |
$4,092
17,957
kWh
|
$2,499
-
kW-mo/yr
|
$63 | |
05 | 2.9114: Use solar heat to make electricty | $111,629 | $154,568 |
$48,816
214,200
kWh
|
$62,813
-
kW-mo/yr
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $24,771 | $37,377 |
$13,952
61,225
kWh
|
$10,819
-
kW-mo/yr
|
- | |
07 | 2.2625: Chill water to the highest temperature possible | $473 | - |
$267
1,172
kWh
|
$206
-
kW-mo/yr
|
- | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $20,560 | $30,577 |
$11,594
50,874
kWh
|
$8,966
-
kW-mo/yr
|
- | |
09 | 2.3141: Use battery storage for demand control | $72,872 | - |
$(-6,109.0)
(-26,806)
kWh
|
$78,981
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $269,965 | $231,333 |
$75,793
332,578
kWh
|
$194,109
-
kW-mo/yr
|
$63 | ||
TOTAL IMPLEMENTED | $6,654 | $4,172 |
$4,092
17,957
kWh
|
$2,499
-
kW-mo/yr
|
$63 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs