Assessment Year | 2021 |
---|---|
Principal Product | DNA Sequencing Devices |
NAICS | 334516: Analytical Laboratory Instrument Manufacturing |
SIC | 3826: Laboratory Analytical Instruments |
Sales Range | $1 M to 5M |
# of Employees | 500 |
Plant Area |
316,000
ft2
|
Annual Production | 1,000
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $142,745 | 671,514 |
kWh
|
$0.21 |
Electricity Demand | $76,838 | 978 |
kW-mo/yr
|
$78.57 |
Electricity Fees | $4,792 | - |
|
- |
TOTAL YEARLY COSTS | $224,375 | |||
RECOMMENDED SAVINGS* | $125,380 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,059 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,059 | $4,547 |
$10,343
48,654
kWh
|
$7,644
-
kW-mo/yr
|
$72 | |
02 | 2.4322: Use or replace with energy efficient substitutes | $23,715 | $4,000 |
$15,418
72,524
kWh
|
$8,297
-
kW-mo/yr
|
- | |
03 | 2.9114: Use solar heat to make electricty | $83,606 | $387,000 |
$76,511
359,882
kWh
|
$7,095
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $125,380 | $395,547 |
$102,272
481,060
kWh
|
$23,036
-
kW-mo/yr
|
$72 | ||
TOTAL IMPLEMENTED | $18,059 | $4,547 |
$10,343
48,654
kWh
|
$7,644
-
kW-mo/yr
|
$72 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs