Assessment Year | 2021 |
---|---|
Principal Product | Shower Door/Glass Enclosures |
NAICS | 327211: Flat Glass Manufacturing |
SIC | 3211: Flat Glass |
Sales Range | $1 M to 5M |
# of Employees | 30 |
Plant Area |
50,000
ft2
|
Annual Production | 1,000,000
units
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $46,611 | 529,248 |
kWh
|
$0.088 |
Electricity Demand | $86,935 | 3,605 |
kW-mo/yr
|
$24.12 |
Electricity Fees | $7,639 | - |
|
- |
TOTAL YEARLY COSTS | $141,185 | |||
RECOMMENDED SAVINGS* | $37,769 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,155 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $24,573 | $9,015 |
$14,455
164,080
kWh
|
$10,118
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,083 | $11,396 |
$4,610
52,314
kWh
|
$3,234
-
kW-mo/yr
|
$239 | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,958 | - |
$3,958
44,925
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,155 | $300 |
$815
9,246
kWh
|
$340
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $37,769 | $20,711 |
$23,838
270,565
kWh
|
$13,692
-
kW-mo/yr
|
$239 | ||
TOTAL IMPLEMENTED | $1,155 | $300 |
$815
9,246
kWh
|
$340
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs