Assessment Year | 2021 |
---|---|
Principal Product | Surfactants, Detergents |
NAICS | 325611: Soap and Other Detergent Manufacturing |
SIC | 2841: Soap and Other Detergents, Except Specialty Cleaners |
Sales Range | $10 M to 50M |
# of Employees | 32 |
Plant Area |
47,100
ft2
|
Annual Production | 133,350,000
lb
|
Production Hrs. Annual | 8,050
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $623,409 | 6,128,762 |
kWh
|
$0.10 |
Electricity Demand | $191,283 | 10,870 |
kW-mo/yr
|
$17.60 |
Electricity Fees | $66,077 | - |
|
- |
Natural Gas | $136,825 | 38,096 |
MMBtu
|
$3.59 |
TOTAL YEARLY COSTS | $1,017,594 | |||
RECOMMENDED SAVINGS* | $91,383 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $78,426 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7425: Clean or color roof to reduce solar load | $30,193 | $22,050 |
$21,199
208,442
kWh
|
$8,994
-
kW-mo/yr
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $5,709 | $10,350 |
$4,536
44,610
kWh
|
$1,173
-
kW-mo/yr
|
- | - | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $5,824 | $24,300 |
$4,197
41,258
kWh
|
$1,627
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,424 | $1,815 |
$1,046
10,288
kWh
|
$361
-
kW-mo/yr
|
- | $17 | |
05 | 2.7135: Install occupancy sensors | $203 | $387 |
$203
1,997
kWh
|
- | - | - | |
06 | 2.1223: Install smaller boiler (increase high fire duty cycle) | $45,722 | $186,400 | - | - |
$45,722
-
MMBtu
|
- | |
07 | 2.2441: Preheat boiler makeup water with waste process heat | $2,308 | $6,000 | - | - |
$2,308
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $91,383 | $251,302 |
$31,181
306,595
kWh
|
$12,155
-
kW-mo/yr
|
$48,030
-
MMBtu
|
$17 | ||
TOTAL IMPLEMENTED | $78,426 | $214,837 |
$21,402
210,439
kWh
|
$8,994
-
kW-mo/yr
|
$48,030
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs