Assessment Year | 2021 |
---|---|
Principal Product | Fabricated sheet metal products |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
76,000
ft2
|
Annual Production | 1,200,000
units
|
Production Hrs. Annual | 4,845
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $137,537 | 1,243,825 |
kWh
|
$0.11 |
Electricity Demand | $184,550 | 4,186 |
kW-mo/yr
|
$44.09 |
Electricity Fees | $10,297 | - |
|
- |
TOTAL YEARLY COSTS | $332,384 | |||
RECOMMENDED SAVINGS* | $16,034 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,468 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.2622: Replace existing chiller with high efficiency model | $10,223 | $1,000 |
$5,144
46,512
kWh
|
$5,079
-
kW-mo/yr
|
|
02 | 2.7232: Replace existing hvac unit with high efficiency model | $4,425 | $14,300 |
$2,542
22,986
kWh
|
$1,883
-
kW-mo/yr
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,043 | $3,772 |
$496
4,488
kWh
|
$547
-
kW-mo/yr
|
|
04 | 2.4321: Upgrade obsolete equipment | $343 | - |
$343
3,099
kWh
|
- | |
TOTAL RECOMMENDED | $16,034 | $19,072 |
$8,525
77,085
kWh
|
$7,509
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $5,468 | $18,072 |
$3,038
27,474
kWh
|
$2,430
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs