Assessment Year | 2020 |
---|---|
Principal Product | Aircraft Wheels and Brakes |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 59 |
Plant Area |
34,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $83,752 | 873,750 |
kWh
|
$0.096 |
Electricity Demand | $34,526 | 3,933 |
kW-mo/yr
|
$8.78 |
Electricity Fees | $15,876 | - |
|
- |
TOTAL YEARLY COSTS | $134,154 | |||
RECOMMENDED SAVINGS* | $22,264 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,547 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7425: Clean or color roof to reduce solar load | $7,822 | $17,000 |
$6,388
66,611
kWh
|
$1,434
-
kW-mo/yr
|
|
02 | 2.7232: Replace existing hvac unit with high efficiency model | $8,897 | $3,900 |
$7,081
73,834
kWh
|
$1,816
-
kW-mo/yr
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,547 | $225 |
$2,040
21,282
kWh
|
$507
-
kW-mo/yr
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,307 | $5,611 |
$1,541
16,077
kWh
|
$766
-
kW-mo/yr
|
|
05 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $691 | $1,720 |
$691
7,203
kWh
|
- | |
TOTAL RECOMMENDED | $22,264 | $28,456 |
$17,741
185,007
kWh
|
$4,523
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $2,547 | $225 |
$2,040
21,282
kWh
|
$507
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs