Assessment Year 2020
Principal Product Vinyl Floor Tiles
NAICS 327120: Clay Building Material and Refractories Manufacturing
SIC 3253: Ceramic Wall and Floor Tile
Sales Range $1
M
to 5
M
# of Employees 117
Plant Area 225,869
ft2
Annual Production 127,920,708
units
Production Hrs. Annual 5,760
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,091,548 16,225,982
kWh
Electricity Demand $844,632 42,115
kW-mo/yr
Natural Gas $143,261 42,032
MMBtu
TOTAL YEARLY COSTS $2,079,441
RECOMMENDED SAVINGS* $32,935 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,259

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $14,538 $12,557 $8,972
133,299
kWh
$5,566
-
kW-mo/yr
02 2.7134: Use photocell controls $4,341 $4,995 $4,341
64,496
kWh
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,858 $13,600 $3,613
53,690
kWh
$2,245
-
kW-mo/yr
04 2.4133: Use most efficient type of electric motors $3,520 $11,623 $2,098
31,175
kWh
$1,422
-
kW-mo/yr
05 2.7135: Install occupancy sensors $2,043 $900 $2,043
30,371
kWh
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,377 $45 $849
12,628
kWh
$528
-
kW-mo/yr
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,259 $75 $1,008
14,976
kWh
$251
-
kW-mo/yr
TOTAL RECOMMENDED $32,935 $43,795 $22,924
340,635
kWh
$10,011
-
kW-mo/yr
TOTAL IMPLEMENTED $1,259 $75 $1,008
14,976
kWh
$251
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs