Assessment Year | 2019 |
---|---|
Principal Product | Roofing |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 106 |
Plant Area |
66,000
ft2
|
Annual Production | 3,500,000
units
|
Production Hrs. Annual | 3,822
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,240 | 1,550,642 |
kWh
|
$0.069 |
Electricity Demand | $162,443 | 6,008 |
kW-mo/yr
|
$27.04 |
Electricity Fees | $10,757 | - |
|
- |
TOTAL YEARLY COSTS | $279,440 | |||
RECOMMENDED SAVINGS* | $20,346 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,759 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $15,684 | $52,500 |
$6,654
97,122
kWh
|
$9,030
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,956 | $5,187 |
$1,252
18,287
kWh
|
$1,629
-
kW-mo/yr
|
$75 | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,075 | - |
$1,075
15,695
kWh
|
- | - | |
04 | 2.4133: Use most efficient type of electric motors | $631 | $522 |
$279
4,066
kWh
|
$352
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $20,346 | $58,209 |
$9,260
135,170
kWh
|
$11,011
-
kW-mo/yr
|
$75 | ||
TOTAL IMPLEMENTED | $16,759 | $52,500 |
$7,729
112,817
kWh
|
$9,030
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs