Assessment Year | 2019 |
---|---|
Principal Product | Printed Materials |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $10 M to 50M |
# of Employees | 32 |
Plant Area |
46,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 4,310
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,012 | 931,730 |
kWh
|
$0.073 |
Electricity Demand | $170,043 | 7,506 |
kW-mo/yr
|
$22.65 |
Electricity Fees | $24,146 | - |
|
- |
TOTAL YEARLY COSTS | $262,201 | |||
RECOMMENDED SAVINGS* | $34,851 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,851 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $24,520 | $35,000 |
$11,722
160,562
kWh
|
$12,798
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,455 | $8,348 |
$2,589
35,478
kWh
|
$2,746
-
kW-mo/yr
|
$120 | |
03 | 2.4133: Use most efficient type of electric motors | $4,534 | $9,736 |
$2,432
33,314
kWh
|
$2,102
-
kW-mo/yr
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $342 | $760 |
$342
4,690
kWh
|
- | - | |
TOTAL RECOMMENDED | $34,851 | $53,844 |
$17,085
234,044
kWh
|
$17,646
-
kW-mo/yr
|
$120 | ||
TOTAL IMPLEMENTED | $34,851 | $53,844 |
$17,085
234,044
kWh
|
$17,646
-
kW-mo/yr
|
$120 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs