Assessment Year | 2018 |
---|---|
Principal Product | Corrugated Boxes |
NAICS | 322219: Other Paperboard Container Manufacturing |
SIC | 3652: Phonograph Records and Prerecorded Audio Tapes and Disks |
Sales Range | $10 M to 50M |
# of Employees | 82 |
Plant Area |
65,000
ft2
|
Annual Production | 24,774,607
units
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $146,798 | 1,617,757 |
kWh
|
$0.091 |
Electricity Demand | $76,562 | 4,301 |
kW-mo/yr
|
$17.80 |
Electricity Fees | $11,780 | - |
|
- |
TOTAL YEARLY COSTS | $235,140 | |||
RECOMMENDED SAVINGS* | $34,134 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,517 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.3132: Recharge batteries on during off-peak demand periods | $17,517 | $86,400 |
$(-1,349.0)
(-14,865)
kWh
|
$18,866
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,666 | $27,785 |
$6,228
68,670
kWh
|
$2,146
-
kW-mo/yr
|
$292 | |
03 | 2.4133: Use most efficient type of electric motors | $5,302 | $2,468 |
$4,202
46,333
kWh
|
$1,100
-
kW-mo/yr
|
- | |
04 | 2.7134: Use photocell controls | $1,676 | $2,046 |
$1,599
17,626
kWh
|
$77
-
kW-mo/yr
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $973 | $400 |
$973
10,722
kWh
|
- | - | |
TOTAL RECOMMENDED | $34,134 | $119,099 |
$11,653
128,486
kWh
|
$22,189
-
kW-mo/yr
|
$292 | ||
TOTAL IMPLEMENTED | $17,517 | $86,400 |
$(-1,349.0)
(-14,865)
kWh
|
$18,866
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs