ITAC Assessment: SD0558
ITAC logo
ITAC Assessment: SD0558
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Water Reclamation Plant
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $100
M
to 500
M
# of Employees 200
Plant Area 1,500,000
ft2
Annual Production 22,000,000
units
Production Hrs. Annual 8,760
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,516,170 27,120,802
kWh
Electricity Demand $1 104,213
kW-mo/yr
TOTAL YEARLY COSTS $1,516,171
RECOMMENDED SAVINGS* $34,207 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $21,844 $45,396 $21,844
390,778
kWh
02 2.7142: Utilize higher efficiency lamps and/or ballasts $11,568 $90,762 $11,568
206,946
kWh
03 2.4133: Use most efficient type of electric motors $795 $1,723 $795
14,214
kWh
TOTAL RECOMMENDED $34,207 $137,881 $34,207
611,938
kWh
TOTAL IMPLEMENTED - - -