Assessment Year | 2017 |
---|---|
Principal Product | Fire suppression systems |
NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2869: Industrial Organic Chemicals, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 400 |
Plant Area |
286,000
ft2
|
Annual Production | 80,001
units
|
Production Hrs. Annual | 5,876
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $424,765 | 6,923,464 |
kWh
|
$0.061 |
Electricity Demand | $465,940 | 18,702 |
kW-mo/yr
|
$24.91 |
Electricity Fees | $10,803 | - |
|
- |
Natural Gas | $31,304 | 4,305 |
MMBtu
|
$7.27 |
TOTAL YEARLY COSTS | $932,812 | |||
RECOMMENDED SAVINGS* | $39,770 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $31,697 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,809 | $47,543 |
$9,740
158,629
kWh
|
$8,069
-
kW-mo/yr
|
|
02 | 2.7134: Use photocell controls | $4,954 | $5,368 |
$4,396
71,606
kWh
|
$558
-
kW-mo/yr
|
|
03 | 2.4133: Use most efficient type of electric motors | $4,317 | $7,500 |
$2,339
38,094
kWh
|
$1,978
-
kW-mo/yr
|
|
04 | 2.7122: Disconnect ballasts | $4,196 | $2,050 |
$2,295
37,371
kWh
|
$1,901
-
kW-mo/yr
|
|
05 | 2.2696: Use excess cold process fluid for industrial cooling needs | $3,756 | $9,629 |
$2,055
33,464
kWh
|
$1,701
-
kW-mo/yr
|
|
06 | 2.7135: Install occupancy sensors | $2,573 | $5,317 |
$2,573
41,902
kWh
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,113 | $1,500 |
$1,113
18,128
kWh
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,052 | $360 |
$576
9,376
kWh
|
$476
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $39,770 | $79,267 |
$25,087
408,570
kWh
|
$14,683
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $31,697 | $62,138 |
$20,693
337,012
kWh
|
$11,004
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs