ITAC Assessment: SD0534
ITAC logo
ITAC Assessment: SD0534
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Color Printing
NAICS 323111: Commercial Printing (except Screen and Books)
SIC 2752: Commercial Printing, Lithographic
Sales Range $10
M
to 50
M
# of Employees 73
Plant Area 30,000
ft2
Annual Production 6,000
units
Production Hrs. Annual 4,590
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $133,261 1,311,664
kWh
Electricity Demand $274,311 7,159
kW-mo/yr
Electricity Fees $34,902 -
TOTAL YEARLY COSTS $442,474
RECOMMENDED SAVINGS* $48,021 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,276

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7241: Install outside air damper / economizer on hvac unit $17,516 $28,660 $14,052
138,306
kWh
$3,464
-
kW-mo/yr
02 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $12,021 $5,775 $5,698
56,083
kWh
$6,323
-
kW-mo/yr
03 2.7423: Reduce heat gain by window tinting $5,102 $15,750 $2,853
28,081
kWh
$2,249
-
kW-mo/yr
04 2.7142: Utilize higher efficiency lamps and/or ballasts $5,898 $9,052 $2,809
27,660
kWh
$3,089
-
kW-mo/yr
05 2.2693: Use waste heat steam for absorption refrigeration $2,674 $2,863 $1,459
14,363
kWh
$1,215
-
kW-mo/yr
06 2.7134: Use photocell controls $2,143 $1,850 $1,135
11,173
kWh
$1,008
-
kW-mo/yr
07 2.4133: Use most efficient type of electric motors $1,762 $3,097 $880
8,664
kWh
$882
-
kW-mo/yr
08 2.4231: Reduce the pressure of compressed air to the minimum required $357 $200 $357
3,510
kWh
-
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $548 $180 $276
2,712
kWh
$272
-
kW-mo/yr
TOTAL RECOMMENDED $48,021 $67,427 $29,519
290,552
kWh
$18,502
-
kW-mo/yr
TOTAL IMPLEMENTED $18,276 $15,027 $8,864
87,253
kWh
$9,412
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs