Assessment Year | 2016 |
---|---|
Principal Product | Metal Heat Treating |
NAICS | 332811: Metal Heat Treating |
SIC | 3398: Metal Heat Treating |
Sales Range | $10 M to 50M |
# of Employees | 44 |
Plant Area |
36,000
ft2
|
Annual Production | 6,660
pieces
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $109,742 | 1,239,449 |
kWh
|
$0.089 |
Electricity Demand | $89,781 | 3,740 |
kW-mo/yr
|
$24.01 |
Electricity Fees | $7,325 | - |
|
- |
Natural Gas | $113,008 | 73,688 |
MMBtu
|
$1.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,349 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $11,264 | $750 | - |
$11,264
-
kW-mo/yr
|
- | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $10,754 | $16,450 | - | - |
$10,754
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,617 | $7,417 |
$2,212
24,997
kWh
|
$1,340
-
kW-mo/yr
|
- | $65 | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,051 | $2,510 |
$2,004
22,630
kWh
|
$1,047
-
kW-mo/yr
|
- | - | |
05 | 2.7425: Clean or color roof to reduce solar load | $2,666 | $7,316 |
$2,087
23,578
kWh
|
$579
-
kW-mo/yr
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,406 | $1,200 |
$1,570
17,736
kWh
|
$836
-
kW-mo/yr
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,715 | $200 |
$1,715
19,376
kWh
|
- | - | - | |
08 | 2.2511: Insulate bare equipment | $1,494 | $527 | - | - |
$1,494
-
MMBtu
|
- | |
09 | 2.7134: Use photocell controls | $847 | $1,480 |
$847
9,573
kWh
|
- | - | - | |
10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $535 | $144 |
$321
3,632
kWh
|
$214
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $38,349 | $37,994 |
$10,756
121,522
kWh
|
$15,280
-
kW-mo/yr
|
$12,248
-
MMBtu
|
$65 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs