Assessment Year | 2016 |
---|---|
Principal Product | Thermoset Compounds |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 35 |
Plant Area |
72,000
ft2
|
Annual Production | 493,364
lb
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $80,916 | 651,342 |
kWh
|
$0.12 |
Electricity Demand | $60,622 | 3,778 |
kW-mo/yr
|
$16.05 |
Electricity Fees | $7,420 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $93,140 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $93,140 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.1336: Install equipment to utilize waste fuel | $38,152 | $147,781 |
$22,985
185,062
kWh
|
$15,167
-
kW-mo/yr
|
- | |
02 | 2.7425: Clean or color roof to reduce solar load | $17,463 | $69,877 |
$14,850
119,567
kWh
|
$2,613
-
kW-mo/yr
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $16,883 | $11,174 |
$9,839
79,215
kWh
|
$7,044
-
kW-mo/yr
|
- | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $11,728 | $24,400 |
$6,833
55,022
kWh
|
$4,895
-
kW-mo/yr
|
- | |
05 | 2.4226: Use / purchase optimum sized compressor | $3,236 | $1,000 | - |
$3,236
-
kW-mo/yr
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,188 | $1,500 |
$1,408
11,337
kWh
|
$780
-
kW-mo/yr
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,341 | $700 |
$1,341
10,802
kWh
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,304 | $3,171 |
$680
5,473
kWh
|
$470
-
kW-mo/yr
|
$154 | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $845 | $36 |
$492
3,963
kWh
|
$353
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $93,140 | $259,639 |
$58,428
470,441
kWh
|
$34,558
-
kW-mo/yr
|
$154 | ||
TOTAL IMPLEMENTED | $93,140 | $259,639 |
$58,428
470,441
kWh
|
$34,558
-
kW-mo/yr
|
$154 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs