| Assessment Year | 2011 |
|---|---|
| Principal Product | Valves and Fittings for Gas Utilities |
| NAICS | 332996: Fabricated Pipe and Pipe Fitting Manufacturing |
| SIC | 3489: Ordnance and Accessories, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
70,000
ft2
|
| Annual Production | 10,000
units
|
| Production Hrs. Annual | 4,250
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $85,906 | 1,258,397 |
kWh
|
$0.068 |
| Electricity Demand | $70,886 | 5,400 |
kW-mo/yr
|
$13.13 |
| Electricity Fees | $6,703 | - |
|
- |
| Natural Gas | $35,712 | 4,603 |
MMBtu
|
$7.76 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,818 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7131: Add area lighting switches | $157 | $100 |
$157
2,295
kWh
|
- | - | |
| 02 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $1,314 | $1,156 | - | - |
$1,314
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,205 | $24,995 |
$15,041
220,218
kWh
|
$8,164
-
kW-mo/yr
|
- | |
| 04 | 2.7145: Install skylights | $8,840 | $24,421 |
$5,730
83,895
kWh
|
$3,110
-
kW-mo/yr
|
- | |
| 05 | 2.2414: Use waste heat from hot flue gases to preheat | $1,302 | $3,800 | - | - |
$1,302
-
MMBtu
|
|
| TOTAL RECOMMENDED | $34,818 | $54,472 |
$20,928
306,408
kWh
|
$11,274
-
kW-mo/yr
|
$2,616
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||