Assessment Year | 2011 |
---|---|
Principal Product | Valves and Fittings for Gas Utilities |
NAICS | 332996: Fabricated Pipe and Pipe Fitting Manufacturing |
SIC | 3489: Ordnance and Accessories, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
70,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $85,906 | 1,258,397 |
kWh
|
$0.068 |
Electricity Demand | $70,886 | 5,400 |
kW-mo/yr
|
$13.13 |
Electricity Fees | $6,703 | - |
|
- |
Natural Gas | $35,712 | 4,603 |
MMBtu
|
$7.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $34,818 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7131: Add area lighting switches | $157 | $100 |
$157
2,295
kWh
|
- | - | |
02 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $1,314 | $1,156 | - | - |
$1,314
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,205 | $24,995 |
$15,041
220,218
kWh
|
$8,164
-
kW-mo/yr
|
- | |
04 | 2.7145: Install skylights | $8,840 | $24,421 |
$5,730
83,895
kWh
|
$3,110
-
kW-mo/yr
|
- | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $1,302 | $3,800 | - | - |
$1,302
-
MMBtu
|
|
TOTAL RECOMMENDED | $34,818 | $54,472 |
$20,928
306,408
kWh
|
$11,274
-
kW-mo/yr
|
$2,616
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs