| Assessment Year | 2011 |
|---|---|
| Principal Product | Noodles, Fortune cookies |
| NAICS | 311824: Dry Pasta, Dough, and Flour Mixes Manufacturing from Purchased Flour |
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
35,000
ft2
|
| Annual Production | 8,500,000
lb
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $98,677 | 1,226,080 |
kWh
|
$0.080 |
| Electricity Demand | $42,316 | 3,398 |
kW-mo/yr
|
$12.45 |
| Electricity Fees | $1,800 | - |
|
- |
| Natural Gas | $102,060 | 15,622 |
MMBtu
|
$6.53 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,909 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,502 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,239 | - |
$1,239
15,391
kWh
|
- | - | |
| 02 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $2,059 | $800 | - | - |
$2,059
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $214 | $100 |
$118
1,496
kWh
|
$96
-
kW-mo/yr
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,412 | $800 |
$1,107
13,574
kWh
|
$305
-
kW-mo/yr
|
- | |
| 05 | 2.7135: Install occupancy sensors | $204 | $427 |
$204
2,539
kWh
|
- | - | |
| 06 | 2.2622: Replace existing chiller with high efficiency model | $3,408 | $8,000 |
$2,512
31,205
kWh
|
$896
-
kW-mo/yr
|
- | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,373 | $8,285 |
$3,373
41,895
kWh
|
- | - | |
| TOTAL RECOMMENDED | $11,909 | $18,412 |
$8,553
106,100
kWh
|
$1,297
-
kW-mo/yr
|
$2,059
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,502 | $1,227 |
$1,443
17,930
kWh
|
- |
$2,059
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs