Assessment Year | 2011 |
---|---|
Principal Product | Sheet Metal HVAC Duct |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
70,000
ft2
|
Annual Production | 456,000
lb
|
Production Hrs. Annual | 3,570
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,109 | 473,892 |
kWh
|
$0.10 |
Electricity Demand | $12,009 | 1,427 |
kW-mo/yr
|
$8.42 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,715 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,286 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $213 | - |
$213
2,097
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,286 | $500 |
$834
8,218
kWh
|
$452
-
kW-mo/yr
|
|
03 | 2.7135: Install occupancy sensors | $89 | $98 |
$89
881
kWh
|
- | |
04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $817 | $2,000 |
$817
8,051
kWh
|
- | |
05 | 2.7425: Clean or color roof to reduce solar load | $4,310 | $10,000 |
$4,310
42,467
kWh
|
- | |
TOTAL RECOMMENDED | $6,715 | $12,598 |
$6,263
61,714
kWh
|
$452
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $1,286 | $500 |
$834
8,218
kWh
|
$452
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs