| Assessment Year | 2010 |
|---|---|
| Principal Product | Packaging |
| NAICS | 488991: Packing and Crating |
| SIC | 4783: Packing and Crating |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
7,000
ft2
|
| Annual Production | 1,000
pieces
|
| Production Hrs. Annual | 4,550
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $46,116 | 532,334 |
kWh
|
$0.087 |
| Electricity Demand | $46,571 | 2,489 |
kW-mo/yr
|
$18.71 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,051 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $340 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,033 | $100 |
$1,033
11,934
kWh
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $340 | $100 |
$340
3,940
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,115 | $587 |
$1,115
12,874
kWh
|
- | |
| 04 | 2.7232: Replace existing hvac unit with high efficiency model | $2,424 | $2,000 |
$1,152
13,300
kWh
|
$1,272
-
kW-mo/yr
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $945 | $2,000 |
$619
7,153
kWh
|
$326
-
kW-mo/yr
|
|
| 06 | 2.7425: Clean or color roof to reduce solar load | $194 | $500 |
$194
2,240
kWh
|
- | |
| TOTAL RECOMMENDED | $6,051 | $5,287 |
$4,453
51,441
kWh
|
$1,598
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $340 | $100 |
$340
3,940
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs