Assessment Year | 2010 |
---|---|
Principal Product | Packaging |
NAICS | 488991: Packing and Crating |
SIC | 4783: Packing and Crating |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
7,000
ft2
|
Annual Production | 1,000
pieces
|
Production Hrs. Annual | 4,550
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $46,116 | 532,334 |
kWh
|
$0.087 |
Electricity Demand | $46,571 | 2,489 |
kW-mo/yr
|
$18.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,051 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $340 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,033 | $100 |
$1,033
11,934
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $340 | $100 |
$340
3,940
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $1,115 | $587 |
$1,115
12,874
kWh
|
- | |
04 | 2.7232: Replace existing hvac unit with high efficiency model | $2,424 | $2,000 |
$1,152
13,300
kWh
|
$1,272
-
kW-mo/yr
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $945 | $2,000 |
$619
7,153
kWh
|
$326
-
kW-mo/yr
|
|
06 | 2.7425: Clean or color roof to reduce solar load | $194 | $500 |
$194
2,240
kWh
|
- | |
TOTAL RECOMMENDED | $6,051 | $5,287 |
$4,453
51,441
kWh
|
$1,598
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $340 | $100 |
$340
3,940
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs