Assessment Year | 2008 |
---|---|
Principal Product | Metal Filing Cabinets |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
110,000
ft2
|
Annual Production | 20,000,000
units
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $125,155 | 1,312,616 |
kWh
|
$0.095 |
Electricity Demand | $65,469 | 3,588 |
kW-mo/yr
|
$18.25 |
Natural Gas | $126,010 | 15,388 |
MMBtu
|
$8.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $112,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,090 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,578 | - |
$4,578
7,091
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,544 | $29,161 |
$12,542
131,539
kWh
|
$6,002
-
kW-mo/yr
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $14,356 | $8,130 |
$9,282
97,397
kWh
|
$5,074
-
kW-mo/yr
|
- | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $1,382 | $4,270 | - | - |
$1,382
-
MMBtu
|
|
05 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $1,071 | $2,035 | - | - |
$1,071
-
MMBtu
|
|
06 | 2.4133: Use most efficient type of electric motors | $2,452 | $2,144 |
$1,649
17,296
kWh
|
$803
-
kW-mo/yr
|
- | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,750 | $5,772 |
$1,750
18,359
kWh
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,928 | $3,189 |
$1,304
13,680
kWh
|
$624
-
kW-mo/yr
|
- | |
09 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $62,662 | $213,472 |
$30,435
319,200
kWh
|
$17,520
-
kW-mo/yr
|
$14,707
-
MMBtu
|
|
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,517 | $720 |
$2,276
23,880
kWh
|
$1,241
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $112,240 | $268,893 |
$63,816
628,442
kWh
|
$31,264
-
kW-mo/yr
|
$17,160
-
MMBtu
|
||
TOTAL IMPLEMENTED | $32,090 | $37,249 |
$22,349
193,486
kWh
|
$8,670
-
kW-mo/yr
|
$1,071
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs