Assessment Year | 2007 |
---|---|
Principal Product | aerosol can packaging |
NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 30 |
Plant Area |
45,000
ft2
|
Annual Production | 18,500,000
pieces
|
Production Hrs. Annual | 2,100
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $146,467 | 750,813 |
kWh
|
$0.20 |
Natural Gas | $13,171 | 1,218 |
MMBtu
|
$10.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,037 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,709 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,231 | $22,654 |
$4,316
43,160
kWh
|
$2,915
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,478 | $11,028 |
$6,478
63,643
kWh
|
- | - | |
03 | 2.7134: Use photocell controls | $5,850 | $3,230 |
$2,514
24,700
kWh
|
$3,336
-
kW-mo/yr
|
- | |
04 | 2.2437: Recover waste heat from equipment | $1,437 | $2,332 | - | - |
$1,437
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $1,041 | $1,664 |
$1,041
10,405
kWh
|
- | - | |
TOTAL RECOMMENDED | $22,037 | $40,908 |
$14,349
141,908
kWh
|
$6,251
-
kW-mo/yr
|
$1,437
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,709 | $33,682 |
$10,794
106,803
kWh
|
$2,915
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs