Assessment Year | 2006 |
---|---|
Principal Product | roof tile |
NAICS | 324122: Asphalt Shingle and Coating Materials Manufacturing |
SIC | 3269: Pottery Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 95 |
Plant Area |
100,000
ft2
|
Annual Production | 30,000,000
pieces
|
Production Hrs. Annual | 8,652
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $301,132 | 9,416,180 |
kWh
|
$0.032 |
Electricity Demand | $140,140 | 16,744 |
kW-mo/yr
|
$8.37 |
Natural Gas | $2,096,318 | 2,824,223 |
MMBtu
|
$0.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $214,782 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1221: Replace obsolete burners with more efficient ones | $134,839 | $448,000 | - | - |
$134,839
-
MMBtu
|
- | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $52,310 | $8,020 | - | - |
$52,310
-
MMBtu
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,389 | $12,675 |
$6,389
88,748
kWh
|
- | - | - | |
04 | 2.7134: Use photocell controls | $1,784 | $2,937 |
$1,349
18,736
kWh
|
$435
-
kW-mo/yr
|
- | - | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $19,460 | $19,500 | - | - | - | $19,460 | |
TOTAL RECOMMENDED | $214,782 | $491,132 |
$7,738
107,484
kWh
|
$435
-
kW-mo/yr
|
$187,149
-
MMBtu
|
$19,460 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs